Evolving interfaces: A comprehensive review of implant-abutment connections


Review Article

Author Details : Nikita Narendra Valvi*, Smita Khalikar, Kishor Mahale, Vilas Rajguru, Sonali Mahajan, Ulhas Tandale

Volume : 12, Issue : 3, Year : 2024

Article Page : 123-129

https://doi.org/10.18231/j.idjsr.2024.024



Suggest article by email

Get Permission

Abstract

Studying the implant-abutment connection is crucial, as it primarily determines the strength and stability of an implant-supported restoration, which, in turn, affects prosthetic stability. Traditionally, BrÄnemark's external hexagon has been used. However, significant complications such as abutment screw loosening, rotational misfit at the implant-abutment interface and microbial penetration have necessitated modifications of the external hexagon and led to the development of internal implant-abutment connection.This review outlines the evolution of various implant-abutment connections from the traditional external hexagon to advanced internal designs. Internal interface designs offer several advantages over the traditional approach. They reduce the vertical height platform for restorative components and distribute lateral loading deep within the implant. These designs also shield the abutment screw and provide long internal wall engagements that create a rigid, unified body resisting joint opening. Additionally, they feature wall engagement with the implant that buffers vibration, offer the potential for a microbial seal, and provide extensive flexibility. Importantly, they allow for the lowering of the restorative interface to the implant level for better aesthetics. These advancements have significantly enhanced the clinical performance and reliability of implant-supported restorations.


Keywords: Implant-abutment interface, External hexagon, Internal hexagon, Conical implant connection, Platform­switching


How to cite : Valvi N N, Khalikar S, Mahale K, Rajguru V, Mahajan S, Tandale U, Evolving interfaces: A comprehensive review of implant-abutment connections. Int Dent J Stud Res 2024;12(3):123-129


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







Article History

Received : 16-07-2024

Accepted : 20-09-2024


View Article

PDF File   Full Text Article


Copyright permission

Get article permission for commercial use

Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.idjsr.2024.024


Article Metrics






Article Access statistics

Viewed: 524

PDF Downloaded: 50